The molecular defect responsible for the shortened beta-spectrin chain variant, spectrin Rouen, was identified by analysis of cDNA and genomic DNA of affected individuals after amplification by the polymerase chain reaction. Peripheral blood reticulocyte RNA was transcribed into cDNA and amplified using primers corresponding to the 3' end of beta-spectrin cDNA. Agarose gel electrophoresis of cDNA amplification products from affected individuals revealed the expected band of 391 bp as well as a shortened band of 341 bp. Nucleotide sequencing of the shortened cDNA amplification product revealed that the sequences corresponding to the penultimate exon of the beta-spectrin gene (exon Y) were absent. This result was confirmed by hybridization of a Southern blot of amplification products with a labeled probe specific for exon Y. Nucleotide sequencing of the proband's amplified genomic DNA corresponding to this region of the beta-spectrin gene revealed a mutation in the 5' donor consensus splice site of the intron downstream of the Y exon, TGG/GTGAGT to TGG/GTTAGT, in one allele. We postulate that this mutation leads to the splicing out or skipping of exon Y, thus producing a shortened beta-spectrin chain. To our knowledge, this is the first documented example of exon skipping as the cause of a shortened beta-spectrin chain in a case of hereditary elliptocytosis. The exon skip results in the loss of the 17 amino acids of exon Y and creates a frameshift with the synthesis of 33 novel amino acids prior to premature chain termination 14 residues upstream of the normal carboxy terminus of the beta-spectrin chain, giving a mutant beta-spectrin chain that is 31 amino acids shorter than the normal chain.
M Garbarz, W T Tse, P G Gallagher, C Picat, M C Lecomte, F Galibert, D Dhermy, B G Forget
Usage data is cumulative from November 2025 through November 2026.
| Usage | JCI | PMC |
|---|---|---|
| Text version | 347 | 25 |
| 197 | 9 | |
| Scanned page | 535 | 2 |
| Citation downloads | 264 | 0 |
| Totals | 1,343 | 36 |
| Total Views | 1,379 | |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.