The electrical nature of active NaCl transport and the significance of a basolateral membrane chloride conductance were examined in isolated perfused rabbit proximal convoluted tubules (PCT). PCT were perfused with a high chloride solution that simulated late proximal tubular fluid and were bathed in an albumin solution that simulated rabbit serum in the control and recovery periods. The electrical nature of NaCl transport was examined by bathing the tubules in a high chloride albumin solution where there were no anion gradients. Volume reabsorption (Jv) during the control and recovery period was 0.56 and 0.51 nl/mm X min, respectively, and 0.45 nl/mm X min when the tubules were bathed in a high chloride bath. The transepithelial potential difference (PD) during the control and recovery periods averaged 2.3 mV, but decreased to 0.0 mV in the absence of anion gradients, which indicated that NaCl transport is electroneutral. Further evidence that NaCl transport is electroneutral was obtained by examining the effect of addition of 0.01 mM ouabain in PCT perfused and bathed with high chloride solutions. The Jv was 0.54 nl/mm X min in the control period and not statistically different from zero after inhibition of active transport. The PD was not different from zero in both periods. Two groups of studies examined the role of basolateral membrane Cl- conductance in NaCl transport. First, depolarizing the basolateral membrane with 2 mM bath Ba++ did not significantly affect Jv or PD. Second, the effect of the presumptive Cl- conductance inhibitor anthracene-9-CO2H was examined. Anthracene-9-CO2H did not significantly affect Jv or PD. In conclusion, these data show that NaCl transport in the PCT is electroneutral and transcellular and provide evidence against a significant role for basolateral membrane chloride conductance in the rabbit PCT.
M Baum, C A Berry
Usage data is cumulative from November 2025 through November 2026.
| Usage | JCI | PMC |
|---|---|---|
| Text version | 369 | 20 |
| 218 | 5 | |
| Scanned page | 776 | 0 |
| Citation downloads | 263 | 0 |
| Totals | 1,626 | 25 |
| Total Views | 1,651 | |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.