To determine the effects of the speed of the erythrocyte membrane chloride shift on pulmonary gas transfer, CO2 exchange and the kinetics of pH equilibration were measured with isolated rat lungs perfused with 20% suspensions of human erythrocytes. The lungs were ventilated with room air, and the inflowing perfusate blood gases were similar to those in mixed venous blood in vivo. All experiments were performed at 37 degrees C. Rates of CO2 excretion were determined by measuring the fraction of CO2 in mixed expired gas in a steady state. The time-course of extracellular pH equilibration in the effluent perfusate was measured in a downstream stopflow pH electrode apparatus. CO2 excretion was reduced by approximately 16% when the lungs were perfused with suspensions containing erythrocytes whose HCO-3/Cl- exchange rates was inhibited, compared with CO2 excretion when the lungs were perfused with normal erythrocyte suspensions. A fall of 0.06 in effluent perfusate extracellular pH was noted during perfusion with inhibited erythrocyte suspensions, in contrast to no observable downstream pH change during perfusion with normal erythrocyte suspensions. These results are in close agreement with the predictions of a theoretical model. Our observations suggest that CO2 transfer in capillary beds will be adversely affected in vivo when the rate of the erythrocyte HCO-3/Cl- exchange is abnormally low. Since a number of commonly used drugs are known to inhibit the chloride shift in human erythrocytes, these findings may have important clinical implications, especially in patients with impaired lung function.
E D Crandall, S J Mathew, R S Fleischer, H I Winter, A Bidani
Usage data is cumulative from December 2023 through December 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 153 | 6 |
63 | 24 | |
Scanned page | 382 | 23 |
Citation downloads | 49 | 0 |
Totals | 647 | 53 |
Total Views | 700 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.