Infusion of glucagon causes only a transient increase in glucose production in normal and diabetic man. To assess the effect of intermittent endogenous hyperglucagonemia that might more closely reflect physiologic conditions, arginine (10 g over 30 min) was infused four times to 8 normal subjects and 13 insulin-dependent diabetic subjects (4 of whom were infused concomitantly with somatostatin to examine effects of arginine during prevention of hyperglucagonemia). Each arginine infusion was separated by 60 min. Diabetic subjects were infused throughout the experiments with insulin at rates (0.07-0.48 mU/kg per min) that had normalized base-line plasma glucose and rates of glucose appearance (Ra) and disappearance (Rd). Basal plasma glucagon and arginine-induced hyperglucagonemia were similar in both groups; basal serum insulin in the diabetics (16±1 μU/ml, P < 0.05) exceeded those of the normal subjects (10±1 μU/ml, P < 0.05) but did not increase with arginine. Serum insulin in normal subjects increased 15-20 μU/ml with each arginine infusion. In both groups each arginine infusion increased plasma glucose and Ra. Increments of Ra in the diabetics exceeded those of normal subjects, (P < 0.02); Rd was similar in both groups. In normal subjects, plasma glucose returned to basal levels after each arginine infusion, whereas in the diabetics hyperglycemia persisted reaching 151±15 mg/dl after the last arginine infusion. When glucagon responses were prevented by somatostatin, arginine infusions did not alter plasma glucose or Ra.
Robert Rizza, Carlos Verdonk, John Miles, F. John Service, John Gerich
Usage data is cumulative from November 2025 through November 2026.
| Usage | JCI | PMC |
|---|---|---|
| Text version | 404 | 7 |
| 172 | 4 | |
| Scanned page | 515 | 0 |
| Citation downloads | 271 | 0 |
| Totals | 1,362 | 11 |
| Total Views | 1,373 | |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.