Oxyhemoglobin dissociation (OHD) curves were performed on whole blood (WB) from 20 patients with anginal pain, normal hemodynamics, and normal coronary arteries, as demonstrated by selective coronary cinearteriography. OHD curves in 19 of 20 patients, from zero to full saturation, were nearly identical to those in normal control subjects with values for P50 (Po2 at 50% saturation and pH 7.4) of 26.7±1.5 (mean±SD of the mean) torr (mm Hg) and red blood cell (RBC) levels of 2,3-diphosphoglyceric acid (2, 3-DPG) of 0.72±0.10 (mean±SD of the mean) M/M hemoglobin (Hb). Normal values for nonsmoking adults were: P50, 26.6±1.4 (mean±SD of the mean) torr: and RBC 2,3-DPG, 0.81±0.09 (mean±SD of the mean) M/M Hb. Mean levels of carbon monoxide were normal at 0.14±0.01 (mean±SEM) ml/100 ml WB in 10 patients who were nonsmokers and 0.45±0.15 (mean±SEM) ml/100 ml WB in 10 smokers. In one patient, a heavy smoker with markedly elevated blood carbon monoxide levels, an abnormal leftward shift of the OHD curve was observed. This was corrected after discontinuation of smoking. In utilizing these methods, we could not detect consistent abnormalities of Hb affinity for oxygen at rest in the patients studied, which suggests that a defect in oxygen transport at rest is an unlikely explanation for the symptoms of chest pain in patients with the anginal syndrome and normal coronary arteriograms.
Pantel S. Vokonas, Peter F. Cohn, Michael D. Klein, Myron B. Laver, Richard Gorlin
Usage data is cumulative from November 2025 through November 2026.
| Usage | JCI | PMC |
|---|---|---|
| Text version | 295 | 11 |
| 254 | 3 | |
| Scanned page | 602 | 0 |
| Citation downloads | 229 | 0 |
| Totals | 1,380 | 14 |
| Total Views | 1,394 | |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.