The formation of ursodeoxycholic acid, the 7 beta-hydroxy epimer of chenodeoxycholic acid, was investigated in three subjects with cerebrotendinous xanthomatosis and in four subjects with gallstones. Total biliary bile acid composition was analyzed by gas-liquid chromatography before and after 4 months of treatment with 0.75 g/day of chenodeoxycholic acid. Individual bile acids were identified by mass spectrometry. Before treatment, bile from cerebrotendinous xanthomatosis (CTX) subjects contained cholic acid, 85%; chenodeoxycholic acid, 7%; deoxycholic acid, 3%; allocholic acid, 3%; and unidentified steroids, 2%; while bile from gallstone subjects contained cholic acid, 45%; chenodeoxycholic acid, 43%; deoxycholic acid, 11%, and lithocholic acid, 1%. In all subjects, 4 months of chenodeoxycholic acid therapy increased the proportion of this bile acid to approximately 80% and decreased cholic acid to 3% of the total biliary bile acids, the remaining 17% of bile acids were identified as ursodeoxycholic acid. After the intravenous injection of [3H]chenodeoxycholic acid, the specific activity of biliary ursodeoxycholic acid exceeded the specific activity of chenodeoxycholic acid, and the resulting specific activity decay curves suggested precursor-product relationships. When [3H]7-ketolithocholic acid was administrated to another patient treated with chenodeoxycholic acid, radioactivity was detected in both the ursodeoxycholic acid and chenodeoxycholic acid fractions. These results indicate that substantial amounts of ursodeoxycholic acid are formed in patients treated with chenodeoxycholic acid. The ursodeoxycholic acid was synthesized from chenodeoxycholic acid presumably via 7-ketolithocholic acid.
G Salen, G S Tint, B Eliav, N Deering, E H Mosbach
Usage data is cumulative from November 2025 through November 2026.
| Usage | JCI | PMC |
|---|---|---|
| Text version | 523 | 25 |
| 209 | 6 | |
| Figure | 0 | 4 |
| Scanned page | 1,031 | 9 |
| Citation downloads | 275 | 0 |
| Totals | 2,038 | 44 |
| Total Views | 2,082 | |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.