Go to JCI Insight
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Advertising
  • Job board
  • Contact
  • Clinical Research and Public Health
  • Current issue
  • Past issues
  • By specialty
    • COVID-19
    • Cardiology
    • Gastroenterology
    • Immunology
    • Metabolism
    • Nephrology
    • Neuroscience
    • Oncology
    • Pulmonology
    • Vascular biology
    • All ...
  • Videos
    • Conversations with Giants in Medicine
    • Video Abstracts
  • Reviews
    • View all reviews ...
    • Complement Biology and Therapeutics (May 2025)
    • Evolving insights into MASLD and MASH pathogenesis and treatment (Apr 2025)
    • Microbiome in Health and Disease (Feb 2025)
    • Substance Use Disorders (Oct 2024)
    • Clonal Hematopoiesis (Oct 2024)
    • Sex Differences in Medicine (Sep 2024)
    • Vascular Malformations (Apr 2024)
    • View all review series ...
  • Viewpoint
  • Collections
    • In-Press Preview
    • Clinical Research and Public Health
    • Research Letters
    • Letters to the Editor
    • Editorials
    • Commentaries
    • Editor's notes
    • Reviews
    • Viewpoints
    • 100th anniversary
    • Top read articles

  • Current issue
  • Past issues
  • Specialties
  • Reviews
  • Review series
  • Conversations with Giants in Medicine
  • Video Abstracts
  • In-Press Preview
  • Clinical Research and Public Health
  • Research Letters
  • Letters to the Editor
  • Editorials
  • Commentaries
  • Editor's notes
  • Reviews
  • Viewpoints
  • 100th anniversary
  • Top read articles
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Advertising
  • Job board
  • Contact
Pulsatile uptake of CO in the human lung
Harold A. Menkes, … , Robert E. Forster II, Arthur B. DuBois
Harold A. Menkes, … , Robert E. Forster II, Arthur B. DuBois
Published February 1, 1970
Citation Information: J Clin Invest. 1970;49(2):335-345. https://doi.org/10.1172/JCI106242.
View: Text | PDF
Research Article

Pulsatile uptake of CO in the human lung

  • Text
  • PDF
Abstract

The instantaneous uptake of CO in the lungs was measured with a water-filled body plethysmograph in normal man. First, control measurements of plethysmograph pressure were made while the subject held his breath for 7 sec after breathing gas mixtures prepared to bring his alveolar PO2 and PCO2 close to mixed venous levels. Then, CO uptake measurements were made while he held his breath after inhaling the same gas mixtures with added CO (2.0%). The change in lung volume on CO minus the change in lung volume during the control measurement was a measure of the CO uptake in the lungs. Cardiopneumatic changes in lung gas volume were subtracted electrically. All of five subjects showed pulsatile CO uptake. The mean CO uptake was 103 ml/min. A peak uptake of 2.0 (range 1.6-2.3) times the mean uptake occurred 0.3-0.4 sec after the R wave of the EKG and a minimum uptake of 0.4 (range 0.2-0.5) times the mean uptake occurred during the tenth of a second before the R wave of the EKG. These results suggest that pulmonary capillary blood volume is pulsatile during the cardiac cycle.

Authors

Harold A. Menkes, Kazuaki Sera, Robert M. Rogers, Richard W. Hyde, Robert E. Forster II, Arthur B. DuBois

×

Full Text PDF

Download PDF (1.54 MB)

Copyright © 2025 American Society for Clinical Investigation
ISSN: 0021-9738 (print), 1558-8238 (online)

Sign up for email alerts