Plasma and platelet factor XIII levels were measured in normal human donors and in a patient congenitally deficient in factor XIII. The purpose of these experiments was to study the role of platelet factor XIII in blood coagulation. On polyacrylamide disc electrophoresis, factor XIII activity in extracts of washed normal platelets appeared as a single peak. This peak was missing or very low when factor XIII-deficient platelet extract was used. The patient was also studied before and after transfusion of fresh frozen plasma. Before transfusion, factor XIII activity could not be detected in the patient's plasma or platelet extracts. 24 hr after transfusion the plasma factor XIII level was still at the anticipated value, but factor XIII activity could not be detected in the platelet extracts. These experiments imply that plasma factor XIII was not transported across the platelet membrane in measurable quantities in vivo. This suggests that platelet factor XIII is a true platelet component and originates in the platelet precursor, the megakaryocyte. Thrombelastographic studies suggest that platelet factor XIII participates in the coagulation process. Thrombelastograms of factor XIII-deficient samples had decreased maximum amplitude and clot elasticity values. The abnormalities were fully corrected by the addition of washed normal platelets to factor XIII-deficient plasma; preincubation of the normal platelets in the deficient plasma had no additional effect. This indicates that platelet factor XIII is immediately available during clot formation.
Jan McDonagh, R. P. McDonagh Jr., J.-M. Delâge, Robert H. Wagner
Usage data is cumulative from December 2023 through December 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 144 | 0 |
86 | 23 | |
Scanned page | 244 | 1 |
Citation downloads | 42 | 0 |
Totals | 516 | 24 |
Total Views | 540 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.