Glucose-dependent insulinotropic polypeptide (GIP) is a 42-amino acid peptide produced by K cells of the mammalian proximal small intestine and is a potent stimulant of insulin release in the presence of hyperglycemia. However, its relative physiological importance as a postprandial insulinotropic agent is unknown. Using LGIPR2 cells stably transfected with rat GIP receptor cDNA, GIP (1-42) stimulation of cyclic adenosine monophosphate (cAMP) production was inhibited in a concentration-dependent manner by GIP (7-30)-NH2. Competition binding assays using stably transfected L293 cells demonstrated an IC50 for GIP receptor binding of 7 nmol/liter for GIP (1-42) and 200 nmol/liter for GIP (7-30)-NH2, whereas glucagonlike peptide-1 (GLP-1) binding to its receptor on ++betaTC3 cells was minimally displaced by GIP (7-30)-NH2. In fasted anesthetized rats, GIP (1-42) stimulated insulin release in a concentration-dependent manner, an effect abolished by the concomitant intraperitoneal administration of GIP (7-30)-NH2 (100 nmol/ kg). In contrast, glucose-, GLP-1-, and arginine-stimulated insulin release were not affected by GIP (7-30)-NH2. In separate experiments, GIP (7-30)-NH2 (100 nmol/kg) reduced postprandial insulin release in conscious rats by 72%. It is concluded that GIP (7-30)-NH2 is a GIP-specific receptor antagonist and that GIP plays a dominant role in mediating postprandial insulin release.
C C Tseng, T J Kieffer, L A Jarboe, T B Usdin, M M Wolfe
Usage data is cumulative from November 2023 through November 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 267 | 69 |
85 | 43 | |
Citation downloads | 43 | 0 |
Totals | 395 | 112 |
Total Views | 507 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.