Tryptase, a protease produced by all mast cells, was evaluated as a clinical marker of systemic mastocytosis. Two sandwich immunoassays were evaluated, one which used the mAb G5 for capture, the other which used B12 for capture. The B12 capture assay measured both recombinant alpha- and beta-tryptase, whereas the G5 capture assay measured primarily recombinant beta-tryptase. G5 binds with low affinity to both recombinant alpha-tryptase and tryptase in blood from normal and nonacute mastocytosis subjects, and binds with high affinity to recombinant beta-tryptase, tryptase in serum during anaphylaxis, and tryptase stored in mast cell secretory granules. B12 recognizes all of these forms of tryptase with high affinity. As reported previously, during systemic anaphylaxis in patients without known mastocytosis, the ratio of B12- to G5-measured tryptase was always < 5 and approached unity (Schwartz L.B., T.R. Bradford, C. Rouse, A.-M. Irani, G. Rasp, J.K. Van der Zwan and P.-W.G. Van der Linden, J. Clin. Immunol. 14:190-204). In this report, most mastocytosis patients with systemic disease have B12-measured tryptase levels that are elevated (> 20 ng/ml) and are at least 10-fold greater than the corresponding G5-measured tryptase level. Most of those subjects with B12-measured tryptase levels of < 20 ng/ml had only cutaneous manifestations. The B12 assay for alpha-tryptase and beta-tryptase, particularly when performed in conjunction with the G5 assay for beta-tryptase, provides a more precise measure of mast cell involvement than currently available assessments, a promising potential screening test for systemic mastocytosis and may provide an improved means to follow disease progression and response to therapy.
L B Schwartz, K Sakai, T R Bradford, S Ren, B Zweiman, A S Worobec, D D Metcalfe
Usage data is cumulative from March 2024 through March 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 395 | 36 |
85 | 59 | |
Figure | 0 | 1 |
Scanned page | 407 | 75 |
Citation downloads | 60 | 0 |
Totals | 947 | 171 |
Total Views | 1,118 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.