Circulating antiphospholipid antibodies (aPL) are associated with a syndrome of thrombosis, recurrent fetal loss, and thrombocytopenia. We have demonstrated the activation of cultured human umbilical vein endothelial cells (HUVEC) by IgG from patients with anticardiolipin antibodies (aCL). Incubation of HUVEC for 4 h with purified IgG (100 micrograms/ml) from patients with high-titer aCL induced a 2.3-fold increase in monocyte adhesion over that seen in HUVEC incubated with IgG's from normal subjects. The effect of aCL was not attributable to LPS contamination, Fc receptors, or immune complexes. Monocyte adhesion was not induced when the aCL were added in serum-free media but was restored by the addition of purified beta 2GP1, previously described as a necessary cofactor for aCL reactivity. Purified rabbit polyclonal IgG raised against beta 2GP1 also induced monocyte adhesion when incubated with HUVEC. Preadsorption of patient serum with cardiolipin reduced monocyte adhesion by 60%. Immunofluorescent microscopy demonstrated that endothelial cells incubated with patient IgG expressed cell adhesion molecules, including E-selectin, vascular cell adhesion molecule-1, and intracellular adhesion molecule-1. These data support the hypothesis that aPL activate vascular endothelial cells, thereby leading to a pro-thrombotic state.
R Simantov, J M LaSala, S K Lo, A E Gharavi, L R Sammaritano, J E Salmon, R L Silverstein
Usage data is cumulative from March 2024 through March 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 315 | 9 |
61 | 43 | |
Figure | 0 | 1 |
Scanned page | 356 | 7 |
Citation downloads | 57 | 0 |
Totals | 789 | 60 |
Total Views | 849 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.