To determine if peripheral angiotensin II (Ang II) prejunctional receptors facilitating NE release exist in humans, we used [3H]NE kinetic methodology to measure forearm NE spillover during intrabrachial arterial Ang II infusions in eight normal male subjects. We used the following protocol to optimize conditions for demonstrating these receptors: (a) lower body negative pressure (-15 mmHg) to increase sympathetic nerve activity to skeletal muscle; and (b) intraarterial nitroprusside to maintain a high constant forearm blood flow (approximately 10 ml/min.100 ml) to maximize the proportion of neuronally released NE that spills over into the circulation. During lower body negative pressure, the following were infused intraarterially for three consecutive 20-min periods: saline, Ang II (4 ng/min), and Ang II (16 ng/min). During the Ang II infusions, forearm venous NE increased significantly from 173 to 189 and 224 pg/ml (P < 0.01), and forearm NE spillover increased from 384 to 439 and 560 ng/min.100 ml (P < 0.05 for high Ang II). Forearm NE clearance was unchanged. During low and high dose Ang II, the plasma venous Ang II concentrations were 25 and 97 pM, respectively. Since normal subjects increase plasma Ang II from 4 to 20-22 pM with exercise, standing, or diuretic administration, and patients with severe congestive heart failure can have a plasma Ang II of approximately 25 pM at rest, we suggest that Ang II might facilitate NE release in severe congestive heart failure, especially under conditions of stress.
B Clemson, L Gaul, S S Gubin, D M Campsey, J McConville, J Nussberger, R Zelis
Usage data is cumulative from May 2024 through May 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 137 | 5 |
56 | 16 | |
Scanned page | 383 | 3 |
Citation downloads | 71 | 0 |
Totals | 647 | 24 |
Total Views | 671 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.