Left ventricular hypertrophy (LVH) potentiates reperfusion-associated ventricular fibrillation. To study the mechanism responsible, patch-clamp techniques were used to evaluate transmembrane ionic currents during "reperfusion" after a CN(-)-induced metabolic surrogate for ischemia in isolated myocytes from a feline model of experimental LVH. Reperfusion caused the generation of early afterdepolarizations (EADs) from an average take-off potential of -33 mV in LVH cells but not in cells from normal hearts. 10 min after initiating reperfusion of normal cells, action potential duration (APD) at 50% repolarization (APD50) lengthened from 198 +/- 41 to 233 +/- 57 ms whereas in LVH cells APD50 lengthened from 262 +/- 84 to 349 +/- 131 ms (P < 0.05). Among the LVH cells, APD50 lengthening was significantly greater in the cells that had developed EADs. During reperfusion, steady state outward current in the voltage range of the action potential plateau (between -20 and +20 mV) was reduced from the control values in LVH cells but not in normal cells. Reperfusion-related reduction of steady state outward current in LVH cells was abolished under experimental conditions in which L-type Ca2+ current was isolated from other classes of currents whereas it was still observed under the condition in which pure K+ currents could be recorded. Thus, reduction of steady state outward current due to the reduction of outward K+ current over the action potential plateau voltage range appears to be responsible for an excessive prolongation of APD, leading to the development of EADs.
T Furukawa, A L Bassett, N Furukawa, S Kimura, R J Myerburg
Usage data is cumulative from March 2024 through March 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 111 | 2 |
68 | 13 | |
Scanned page | 431 | 2 |
Citation downloads | 51 | 0 |
Totals | 661 | 17 |
Total Views | 678 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.