Using continuous microperfusion techniques, we studied the load dependence of bicarbonate reabsorption along cortical distal tubules of the rat kidney and their bicarbonate permeability. Net bicarbonate transport was evaluated from changes in tracer inulin concentrations and total CO2 measurements by microcalorimetry. Bicarbonate permeability was estimated from the flux of total CO2 along known electrochemical gradients into bicarbonate-and chloride-free perfusion solution containing 10(-4) M acetazolamide. Transepithelial potential differences were measured with conventional glass microelectrodes. Significant net bicarbonate reabsorption occurred at luminal bicarbonate levels from 5 to 25 mM, and at perfusion rates from 5 to 30 nl/min. Bicarbonate reabsorption increased in a load-dependent manner, both during increments in luminal bicarbonate concentration or perfusion rate, reaching saturation at a load of 250 pmol/min with a maximal reabsorption rate of approximately 75 pmol/min.mm. Rate of bicarbonate reabsorption was flow dependent at luminal concentrations of 10 but not at 25 mM. During chronic metabolic alkalosis, maximal rates of reabsorption were significantly reduced to 33 pmol/min.mm. The bicarbonate permeability was 2.32 +/- 0.13 x 10(-5) cm/s in control rats, and 2.65 +/- 0.26 x 10(-5) cm/s in volume-expanded rats. Our data indicate that at physiological bicarbonate concentrations in the distal tubule passive bicarbonate fluxes account for only 16-21% of net fluxes. At high luminal bicarbonate concentrations, passive bicarbonate reabsorption contributes moderately to net reabsorption of this anion.
Y L Chan, G Malnic, G Giebisch
Usage data is cumulative from April 2024 through April 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 71 | 0 |
41 | 17 | |
Scanned page | 228 | 4 |
Citation downloads | 44 | 0 |
Totals | 384 | 21 |
Total Views | 405 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.