Escherichia coli hemolysin has been implicated as a pathogenicity factor in extraintestinal E. coli infections including sepsis. In the present study the effects of intravascular administration of hemolysin were investigated in isolated blood-free perfused rabbit lungs. Low concentrations of the toxin in the perfusate (0.05-5 hemolytic units/ml, corresponding to approximately 5-500 ng/ml), caused a dose- and time-dependent release of potassium, thromboxane A2, and prostaglandin I2, but not of lactate dehydrogenase, into the recirculating medium, as well as a dose-dependent liberation of the prostanoids into the bronchoalveolar space. These events were paralleled by a dose-dependent pulmonary hypertension, and studies with different inhibitors collectively indicated that the vasoconstrictor response was mediated predominantly by pulmonary thromboxane generation. In addition, E. coli hemolysin elicited a protracted, dose-dependent increase in the lung capillary filtration coefficient, which was independent of the prostanoid-mediated pressor response and resulted in severe pulmonary edema formation. We conclude that E. coli hemolysin can elicit thromboxane-mediated pulmonary hypertension combined with severe vascular leakage in isolated lungs in the absence of circulating inflammatory cells and humoral mediator systems, mimicking the key events in the development of acute respiratory failure in states of septicemia.
W Seeger, H Walter, N Suttorp, M Muhly, S Bhakdi
Usage data is cumulative from March 2024 through March 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 125 | 1 |
53 | 17 | |
Scanned page | 317 | 2 |
Citation downloads | 55 | 0 |
Totals | 550 | 20 |
Total Views | 570 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.