Currently available noninvasive techniques are unable to rapidly assess artery patency and tissue viability during acute myocardial infarction. In prior studies, rubidium-82 (Rb-82), a short-lived positron emitter obtained from a generator, was validated as an indicator of flow with a model that included the rate constants for transfer into and out of the cell. Accordingly, in the current study, 20 open-chested dogs with experimental infarction were studied serially at base line, after coronary occlusion, and at reperfusion. Time-activity curves acquired with beta probes on the epicardial surface were used to measure flow and net transfer of rubidium. Flow decreased to 0.41 +/- 0.08 ml/min per gram during occlusion and increased to 2.73 +/- 0.56 ml/min per gram in potentially viable ischemic tissue, whereas flows were 0.32 +/- 0.08 during occlusion (P less than 0.05 vs. viable) and 1.58 ml/min per gram (P less than 0.002 vs. viable) in irreversibly injured tissue. The transfer rate constant for Rb-82, kT, at base line was +1.22 +/- 0.60 X 10(-3) s-1 and did not change significantly during occlusion in viable vs. nonviable samples (+1.41 +/- 1.27 vs. +0.93 +/- 1.51 X 10(-3) s-1, respectively), except that 4 out of 11 nonviable tissue samples had negative kTs. At reperfusion, viable myocardial samples were all positive (+1.26 +/- 1.58 X 10(-3) s-1), whereas all irreversibly injured tissues had a negative kT, indicating leakage of tracer (-1.50 +/- 1.10 X 10(-3) s-1, P less than 0.001). This study suggests that Rb-82 time-activity curves can be useful to determine patency of an infarct related artery and potential viability after reperfusion during myocardial infarction.
R A Goldstein
Usage data is cumulative from November 2023 through November 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 116 | 0 |
65 | 26 | |
Scanned page | 249 | 8 |
Citation downloads | 46 | 0 |
Totals | 476 | 34 |
Total Views | 510 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.