To examine the mechanism of mitral flow deceleration in diastole and its potential influence on the genesis of third (S3) and fourth (S4) heart sounds, we simultaneously recorded left atrial and left ventricular pressures (micromanometers), mitral flow velocity (electromagnetic catheter-tip flow velocity meter), and internal and external phonocardiograms in 25 open-chest dogs. Diastolic time intervals, transmitral pressure gradients (planimetry), maximum mitral flow velocity, and acceleration and deceleration of flow were measured under different loading conditions. It was found that deceleration of mitral flow in early and late diastole is always caused by a negative transmitral pressure gradient. After volume loading, diastolic pressures, positive (forward) and negative (backward) transmitral pressure gradients, and acceleration and deceleration of flow increased, and an S3 or S4 appeared (20:25 dogs). These sounds occurred during the phase of flow deceleration and could be recorded from the chest wall, inside the left ventricle, and directly from the epicardial surface of the freely exposed left ventricular wall. After balloon occlusion of the inferior vena cava (17:25 dogs), the opposite changes were observed and gallop sounds disappeared. The results indicate that the left ventricular pressure rise in response to filling reverses the transmitral pressure gradient and decelerates flow. Deceleration of inflow by the left ventricular wall in early and late diastole may represent a key mechanism in the genesis of S3 and S4.
F Van de Werf, J Minten, P Carmeliet, H De Geest, H Kesteloot
Usage data is cumulative from May 2024 through May 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 132 | 10 |
47 | 19 | |
Scanned page | 273 | 2 |
Citation downloads | 55 | 0 |
Totals | 507 | 31 |
Total Views | 538 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.