Dual parameter flow cytometry studies (cell DNA content and electronic cell volume) were performed in 220 cases of non-Hodgkin's lymphoma. All cases were characterized as B or T cell malignancies, based on immunologic surface marker characteristics. Aneuploidy by flow cytometry was more common among the B cell lymphomas than among the T cell lymphomas, and was most common among the large B cell lymphomas and B cell lymphomas of intermediate size. Ploidy index distributions showed a prominent hyperdiploid peak, as well as tumor cell populations with near-tetraploid DNA contents. In serial studies, a decrease in ploidy index was observed in association with clinical and histologic transformation in one case. The highest S fractions were observed among the large and intermediate B cell lymphomas and among the aggressive T cell lymphomas. In clinical samples consisting of mixtures of diploid and aneuploid populations, the data on the aneuploid components could often be separated from other components of the mixture in multiparameter studies on the basis of the larger electronic cell volumes of the aneuploid cells. In each case, the aneuploid large cell component almost invariably had a higher S fraction than the residual component(s) of the mixture. Overall, the data are consistent with a model of clonal selection and clonal evolution in the lymphomas in which early cytogenetic abnormalities that involve little or no change in total cell DNA content are followed by cell tetraploidization that is associated with cytogenetic instability and chromosome loss over the course of time.
S E Shackney, A M Levine, R I Fisher, P Nichols, E Jaffe, W H Schuette, R Simon, C A Smith, S J Occhipinti, J W Parker
Usage data is cumulative from May 2024 through May 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 72 | 2 |
34 | 21 | |
Scanned page | 345 | 1 |
Citation downloads | 36 | 0 |
Totals | 487 | 24 |
Total Views | 511 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.