Immunoglobulin G (IgG) bound to platelets is usually detected by one of two general methods: binding of labeled anti-IgG or consumption of anti-IgG. The latter method gives, in general, values 5-10-fold greater than the former under the same conditions. To investigate these discrepancies, we have compared the detection of platelet-bound IgG by a labeled anti-IgG binding assay and by a quantitative antiglobulin consumption test using the same antibodies. The interaction of 125I-labeled monoclonal anti-IgG or polyclonal anti-IgG with washed and IgG-coated platelets was studied. The binding of these ligands to washed normal platelets was largely (50-80%) nonspecific; the binding was not saturable and was only partially inhibitable by excess unlabeled anti-IgG. The binding of anti-IgG to platelets coated with anti-PIA1, a platelet-specific IgG antibody, appeared to be saturable and inhibitable; the dissociation constant (KD) of this IgG-anti-IgG reaction was 4.9 X 10(-9) for monoclonal and 1.4 X 10(-7) for polyclonal anti-IgG. The ratio of sites present on the membrane (determined by 131I-labeled anti-PIA1) to the number of binding sites for anti-IgG determined by Scatchard analysis was 0.53 for monoclonal anti-IgG and 1.3 for polyclonal anti-IgG. The binding of monoclonal anti-IgG to platelet-bound immune complexes or IgG aggregates appeared to be complex. 131I-Labeled IgG was affixed to platelets and was detected by three tests: direct binding of radiolabeled monoclonal anti-IgG and quantitative antiglobulin consumption (QAC) tests, which were quantitated either by measuring directly the amount of radiolabeled anti-IgG consumed from fluid phase (direct QAC), or indirectly by reference to a calibration curve relating the consumption of anti-IgG by known amounts of fluid-phase, non-immune IgG (indirect QAC). The amount of platelet-bound IgG detected by the direct binding of 125I-labeled monoclonal anti-IgG and by the direct QAC approximated that known to be bound to the platelet. The results of the indirect QAC test were 10-fold greater. The discrepancy appears to be due to the fact that there is a difference between the IgG-anti-IgG interaction when IgG is bound to a platelet and when it is in solution or bound to plastic nonspecifically or specifically. This difference results in a falsely high value for platelet-bound IgG when fluid-phase or plastic-bound IgG is used to calibrate the antiglobulin consumption test.
W F Rosse, D V Devine, R Ware
Usage data is cumulative from February 2024 through February 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 123 | 5 |
59 | 22 | |
Scanned page | 274 | 1 |
Citation downloads | 52 | 0 |
Totals | 508 | 28 |
Total Views | 536 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.