Insulin receptors and Type I insulinlike growth factor (IGF) receptors have a similar structure with a major binding subunit of Mr approximately 130,000 linked by disulfide bonds to other membrane proteins to form a Mr greater than 300,000 complex. Both insulin and Type I IGF receptors also interact with both insulin and IGF, although with different binding affinities. We used a panel of human and rabbit sera containing antibodies to insulin receptors to determine whether these sera also interact with Type I IGF receptors. Immunoglobulins from five of five human sera inhibited binding of 125I-insulin and 125I-IGF-I to insulin receptors and Type I IGF receptors in human placenta and human lymphocytes. The rank order of reactivity with both receptors was the same; two sera, however, appeared to be selectively less reactive with the Type I IGF receptor, especially in placenta. Sera from five of seven patients and from a rabbit immunized with purified insulin receptor effectively immunoprecipitated both placental insulin receptors and Type I IGF receptors. Of the remaining sera, one had only a low titer against the insulin receptor and did not immunoprecipitate the IGF receptor, whereas the second serum effectively immunoprecipitated cross-linked and surface-iodinated insulin receptors, but had negligible reactivity against the Type I IGF receptor. These results suggest that most antisera to the insulin receptor also contain antibodies to Type I IGF receptors. Whether both specificities are inherent in the same or different antibody molecules remains to be determined. These data support the hypothesis that the insulin and IGF-I receptors are separate but related molecules, although there remains a small possibility that both receptors are domains on the same protein.
M Kasuga, N Sasaki, C R Kahn, S P Nissley, M M Rechler
Usage data is cumulative from May 2024 through May 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 107 | 1 |
39 | 10 | |
Figure | 0 | 2 |
Scanned page | 324 | 1 |
Citation downloads | 46 | 0 |
Totals | 516 | 14 |
Total Views | 530 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.