The aims were to examine the gas exchange and arterial blood gas abnormalities among patients with scoliosis, and the correlation of these abnormalities with age and severity of deformity. Means among 51 patients were as follows: age 25.4 +/- 17.5 yr, angle of scoliosis 80.2 +/- 29.9 (SD), vital capacity 1.94 +/- 0.91 (SD) (i.e. 60.6 +/- 19.2% of predicted), PaO2 85.8 +/- 12.0 (SD), PaCO2 42.4 +/- 8.0, physiological dead space to tidal volume ratio 0.438 +/- 0.074 (SD), and alveolar-arterial oxygen difference breathing air 14.9 +/- 8.9 (SD). Statistically significant correlations were as follows: the PaCO2 and physiological dead space to tidal volume ratio increased with age, and the PaO2 and alveolar ventilation decreased with age. The PaO2, alveolar ventilation, and tidal volume were inversely related to the angle of scoliosis and directly related to the vital capacity, precent predicted vital capacity, and the compliance of the respiratory system. The physiological dead space to tidal volume ratio and the alveolar-arterial oxygen difference were inversely related to the vital capacity, percent predicted vital capacity, and the compliance of the respiratory system. PaCO2 was directly related to the elastance of the respiratory system. We conclude that ventilation-blood flow maldistribution as a result of deformity of the rib cage was the primary abnormality in gas exchange, and that with age there was progressive deterioration in gas exchange. The age-dependent increase in PaCO2 and decrease in alveolar ventilation were due to the increasing physiological dead space to tidal volume ratio and failure of a compensatory increase in ventilation.
E R Kafer
Usage data is cumulative from May 2024 through May 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 149 | 16 |
42 | 19 | |
Scanned page | 297 | 9 |
Citation downloads | 57 | 0 |
Totals | 545 | 44 |
Total Views | 589 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.