Advertisement
Research Article Free access | 10.1172/JCI107870
Veterans Administration Hospital, Minneapolis, Minnesota 55417
Department of Physiology, University of Minnesota, Minneapolis 55455
Department of Medicine, University of Minnesota, Minneapolis 55455
Find articles by Bond, J. in: JCI | PubMed | Google Scholar
Veterans Administration Hospital, Minneapolis, Minnesota 55417
Department of Physiology, University of Minnesota, Minneapolis 55455
Department of Medicine, University of Minnesota, Minneapolis 55455
Find articles by Levitt, D. in: JCI | PubMed | Google Scholar
Veterans Administration Hospital, Minneapolis, Minnesota 55417
Department of Physiology, University of Minnesota, Minneapolis 55455
Department of Medicine, University of Minnesota, Minneapolis 55455
Find articles by Levitt, M. in: JCI | PubMed | Google Scholar
Published December 1, 1974 - More info
The purpose of the present study was to quantitate the influence of countercurrent exchange on passive absorption of highly diffusible substances from the small intestine of the rabbit. The absorption of carbon monoxide, which is tightly bound to hemoglobin and therefore cannot exchange, was compared to the absorption of four unbound gases (H2, He, CH4, and 133Xe), which should exchange freely. The degree to which the observed absorption of the unbound gases falls below that predicted from CO absorption should provide a quantitative measure of countercurrent exchange.
CO uptake at high luminal Pco is flow-limited and, assuming that villus and central hemoglobin concentrations are equal, the flow that equilibrates with CO (Fco) was calculated to equal 7.24 ml/min/100 g. The observed absorption rate of the unbound gases was from two to four times greater than would have been predicted had their entire uptake been accounted for by equilibration with Fco. This is the opposite of what would occur if countercurrent exchange retarded absorption of the unbound gases.
The unbound gases have both flow- and diffusion-limited components, and Fco should account for only the fraction of absorption that is flow limited. A simple model of perfusion and diffusion made it possible to calculate the fraction of the total uptake of unbound gases that was flow limited. This fraction of the total observed absorption rate was still about 1.8 times greater than predicted by CO absorption. A possible explanation for this discrepancy is that plasma skimming reduces the hemoglobin of villus blood to about 60% of that of central blood. Thus, Fco is actually about 1.7 times greater than initially calculated, and with this correction, there is close agreement between the predicted and observed rates of absorption of each of the unbound gases. We conclude that countercurrent exchange does not influence passive absorption under the conditions of this study.