A new, autosomally inherited abnormal fibrinogen associated with hypofibrinogenemia has been described in several members of a family. Plasma fibrinogen measured either as thrombin-clottable protein or by immunodiffusion revealed a fibrinogen level ranging between 60 and 90 mg/100 ml. The thrombin time of plasma or purified fibrinogen was prolonged and only partially corrected by the addition of calcium. Purified fibrinogen prolonged the thrombin time of normal plasma. Fibrinopeptide release by thrombin was normal in rate and amount, but fibrin monomer aggregation was grossly disturbed, especially in a high ionic strength medium. We have designated this fibrinogen "fibrinogen Philadelphia." Acrylamide gel electrophoresis of mixtures of [121I]normal and [125I]abnormal fibrinogens revealed a slight increase in the anodal mobility of fibrinogen Philadelphia. Similarly, DEAE-cellulose chromatography showed slightly stronger binding of fibrinogen Philadelphia than normal. To elucidate the mechanism responsible for the low plasma fibrinogen concentration, simultaneous metabolic studies of autologous (patient) and homologous (normal) fibrinogen, labeled with 125I and 121I, respectively, were performed in two affected subjects. Autologous fibrinogen half-life was short and the fractional catabolic rate was markedly increased in both family members. In contrast, homologous fibrinogen half-life and fractional catabolic rate were normal. These metabolic studies demonstrate that rapid degradation of fibrinogen Philadelphia is largely responsible for the depressed levels of a plasma fibrinogen. This represents the first example of a mutant plasma protein in which the molecular defect is associated with an altered catabolism.
J Martinez, R R Holburn, S S Shapiro, A J Erslev
Usage data is cumulative from April 2024 through April 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 139 | 3 |
38 | 30 | |
Scanned page | 352 | 2 |
Citation downloads | 44 | 0 |
Totals | 573 | 35 |
Total Views | 608 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.