The release of histaminase activity in plasma after small intravenous of heparin was studied in 85 normal subjects and patients. In normal subjects, plasma histaminase activity (basal level, 1.7±0.1 U/ml, mean ±SEM) increased 1.6±0.2 U/ml after 10 U of heparin/kg, 8.5±2.4 U/ml after 20 U/kg, and 33±4.9 U/ml after 75 U/kg. The extent of the increase varied widely among individuals but in a particular individual the response was constant and dose-dependent. Histaminase activity rose to peak levels within 7-15 min and then declined exponentially with a half-life of 40-120 min. This pattern of response was also observed in two patients with the histaminase-producing tumor, medullary carcinoma of the thyroid. A significantly reduced response was observed, however, in 14 patients with type I hyperlipoproteinemia, a disorder in which high plasma triglyceride levels are associated with low postheparin plasma lipolytic activity. After 10 U heparin/kg, plasma histamine activity increased 0.5±0.2 U/ml, and after 75 U heparin/kg, 10.9±5.6 U/ml. In contrast, in 27 patients with other types of hyperlipoproteinemia in whom postheparin lipolytic activity was normal, the increase (2.4±0.6 U/ml) in plasma histaminase activity after 10 U heparin/kg was not significantly different from that of normal subjects. The reduced response of the plasma histaminase activity to heparin in patients with type I hyperlipoproteinemia did not appear to be due to the presence of lipemia or to an inhibitor of the enzyme in plasma. These findings suggest that many patients with type I hyperlipoproteinemia may have deficient release of both lipolytic and histaminase activities into plasma after heparin administration.
Stephen B. Baylin, Michael A. Beaven, Ronald M. Krauss, Harry R. Keiser
Usage data is cumulative from November 2023 through November 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 140 | 0 |
91 | 17 | |
Scanned page | 312 | 2 |
Citation downloads | 40 | 0 |
Totals | 583 | 19 |
Total Views | 602 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.