Abstract

The effects of coronary artery bypass graft (CAB) and coronary collaterals (CC) on myocardial blood flow (MBF) were studied in 24 patients undergoing 29 CAB's. MBF after CAB was compared to preexisting MBF by intraoperatively injecting 133xenon via distal CAB with proximal CAB first occluded then open. Pressure gradients across bypassed obstructions were measured. The results were correlated with preoperative coronary arteriograms to determine the effects of CC on MBF and postobstructive perfusion pressures. Mean MBF was increased by CAB from 32±6 (se) ml/min per 100 g (CAB occluded) to 118±13 ml/min per 100 g (CAB open). The 133Xe clearance curves with CAB open were resolved into slow (19±2 ml/min per 100 g) and rapid (133±12 ml/min per 100 g) phases, suggesting that MBF remained heterogeneous after CAB. Vessels with less than 80% stenosis by angiography had pressure gradients less than 20 mm Hg across obstructions, high postobstructive perfusion pressures (75±7 mm Hg), and normal MBF (87±6 ml/min per 100 g) even with CAB occluded. Vessels with greater than 80% stenosis or total occlusion by angiography had significant pressure gradients with marked reduction of postobstructive MBF. No significant difference in postobstructive MBF was found when vessels with CC (21±4 ml/min per 100 g) were compared to those without CC (17±4 ml/min per 100 g) (P > 0.4).

Authors

Sidney C. Smith Jr., Richard Gorlin, Michael V. Herman, Warren J. Taylor, John J. Collins Jr.

×