The lysozyme content of human cartilage was measured by incubation of lyophilized, powdered cartilage in a variety of buffers and salt solutions, and the factors controlling the binding of lysozyme within cartilage were studied. Lysozyme was extracted from hyaline cartilage by buffers of pH greater than 9.0 by solutions 1 M in monovalent cations, and by solutions 0.12-0.40 M in divalent cations. The ability of cations to extract lysozyme from cartilage agreed with their known affinities for binding to chondroitin sulfate. The total extractable lysozyme content of five samples of human costal cartilage ranged from 1.45 to 3.36 μg lysozyme per mg of cartilage; for five samples of hyaline cartilage from peripheral joints the range was 0.80-3.03 μg lysozyme per mg of cartilage. Cartilage incubated in excess exogenous lysozyme could bind 0.053 equivalents of lysozyme per equivalent of chondroitin sulfate. Fibrocartilage and synovium from knee joints yielded no detectable lysozyme, despite the fact that synovium, a tissue rich in lysosomes, contained measurable quantities of β-glucuronidase. Lysozyme extraction from cartilage was not augmented by incubation with streptolysin S. When incubation was carried out with mild extraction techniques, lysozyme extraction from cartilage tended to parallel uronic acid release, both as a function of time and from one specimen to another. The active material as lysozyme. Lysozyme occurs in human hyaline cartilage as a counterion to polyanionic glycosaminoglycans. Carextracted from cartilage met five criteria for identification tilage lysozyme appears to be extracellular and nonlysosomal. Degradation of cartilage may contribute to the increased serum and synovial fluid lysozyme levels often present in patients with rheumatoid arthritis.
Robert A. Greenwald, Alan S. Josephson, Herbert S. Diamond, Ambrose Tsang
Usage data is cumulative from May 2024 through May 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 193 | 5 |
58 | 22 | |
Scanned page | 248 | 2 |
Citation downloads | 57 | 0 |
Totals | 556 | 29 |
Total Views | 585 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.