A radioligand assay has been developed for the measurement of unconjugated 17β-estradiol in as little as 0.01 ml of pregnancy plasma employing rabbit uterine cytosol as specific binder and activated charcoal as nonspecific absorbant. Large numbers of samples could be processed simultaneously at relatively little expense and results were obtainable within 3 hr. The procedure was sensitive to 1 ng/ml. No diurnal or positional variations were found. Values from 250 unselected normal patients showed a constantly rising mean plasma E2 from 18 to 35 wk gestation from 4.5 to 14 ng/ml. From 35 to 40 wk, mean E2 rose only to 15 ng/ml and the range of values increased substantially. When 22 normal pregnant subjects were followed serially, rising levels of plasma E2 were found with no significant fall ever seen. By contrast, patients exhibiting fetal distress generally had falling or reduced E2 levels. However, 3 cases of Rh isoimmunization had elevated or normal E2 concentrations even after clearcut evidence of fetal demise. A decrease of 45% in E2 concentration was associated with intraamniotic instillation of hypertonic saline prior to delivery supporting the view that placental conversion of maternal adrenal precursors is responsible for about half of the E2 production in pregnancy. The postpartum clearance of endogenous E2 was measured and found to fit a two compartment model with mean half-time of 22 min and 7 hr. Follicular phase levels of E2 were attained by 35 hr postpartum. The concentration of unconjugated E2 in pregnancy plasma correlated as well with the state of the placenta as other placental hormone measurements and holds promise of being a rapid, inexpensive, and reliable method of following patients with high-risk pregnancies in a variety of clinical settings.
Dan Tulchinsky, Stanley G. Korenman
Usage data is cumulative from June 2024 through June 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 155 | 3 |
52 | 12 | |
Scanned page | 287 | 10 |
Citation downloads | 50 | 0 |
Totals | 544 | 25 |
Total Views | 569 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.