Parotid fluid corticosteroids, substantially comprised of cortisol and cortisone, were previously demonstrated to rise to far greater levels 4 hr after administration of ACTH than they did in the third trimester of pregnancy, although the plasma total corticosteroid concentrations were similar in these two states. It was therefore suggested that only nonproteinbound corticosteroid gains access to parotid fluid. In the present study parotid fluid cortisol and cortisone and plasma dialyzable cortisol concentrations have been measured in normal men before and 2 hr after 40 U ACTH, and, in another group, before and after 10 days of diethystilbestrol (5 mg daily). Total plasma cortisol rose from a mean of 6.3 to 17.9 μg/100 ml after ACTH and from 14.6 to 39.4 mg/100 ml after the estrogen. However parotid fluid cortisol plus cortisone rose from 0.8 to 2.6 μg/100 ml after ACTH and to only 2.2 after estrogen. This rise resembled that of the plasma dialyzable cortisol (control 0.4, ACTH 1.8, estrogen 1.2 μg/100 ml) rather than the increase in total plasma cortisol which was over twice as high after estrogen as after ACTH. Thus parotid fluid corticosteroids seem to be a good measure of nonprotein-bound corticosteroid, the cortisol available to the cell. The total amount of cortisol plus cortisone excreted is approximately constant, independent of parotid fluid flow rate. Cortisone exceeds cortisol in parotid fluid in the basal state, but after ACTH the situation is reversed.
Fred H. Katz, Ira L. Shannon
Usage data is cumulative from June 2024 through June 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 125 | 4 |
47 | 17 | |
Scanned page | 328 | 4 |
Citation downloads | 75 | 0 |
Totals | 575 | 25 |
Total Views | 600 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.