The present investigation was intended to evaluate myocardial inert gas desaturation curves for manifestations of heterogeneous coronary perfusion. The test gas was hydrogen (H2) and blood H2 analyses were performed with a gas chromatograph capable of detecting small but prolonged venous-arterial H2 differences produced by areas of reduced flow. Curves were initially obtained after 4-min left ventricular infusions of H2-saturated saline in six patients with arteriographically proven coronary artery disease, three patients with normal coronary arteries, and nine closed-chest dogs. The dogs were studied before and after embolic occlusion of a portion of the left coronary artery. Although the slopes of their semilogarithmically plotted venous desaturation curves varied with time before embolization, they showed more distinct deviations from single exponentials after embolization (after H2 concentrations had fallen below 15% of their initial values). The human curves divided similarly, those from coronary artery patients deviating appreciably from single exponentials. A similar separation was also evident in studies of coronary venous-arterial H2 differences after 20 min of breathing 2% H2: data were obtained in four dogs before and after coronary embolization, and in three normal patients, and five patients with coronary artery disease. Additional data indicated that the findings were not the result of right atrial admixture in sampled coronary venous blood, although admixture occurred frequently when blood was sampled in the first 2 cm of the coronary sinus (as seen in the frontal projection). Finally, average coronary flows calculated from a given set of data varied significantly with different methods of calculation. Areas of below-average flow seemed likely to be overlooked when single rate constants of desaturation, relatively insensitive analytical techniques, or relatively short periods of saturation and (or) desaturation are employed.
Francis J. Klocke, Robert C. Koberstein, David E. Pittman, Ivan L. Bunnell, David G. Greene, Douglas R. Rosing
Usage data is cumulative from April 2024 through April 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 109 | 0 |
52 | 15 | |
Scanned page | 427 | 4 |
Citation downloads | 50 | 0 |
Totals | 638 | 19 |
Total Views | 657 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.