Short-term preexposure of mononuclear cells to epinephrine inhibits LPS-induced production of TNF, whereas preexposure for 24 h results in increased TNF production. To assess the effects of epinephrine infusions of varying duration on in vivo responses to LPS, the following experiments were performed: (a) Blood obtained from eight subjects at 4-24 h after the start of a 24-h infusion of epinephrine (30 ng/kg per min) produced less TNF after ex vivo stimulation with LPS compared with blood drawn before the start of the infusion, and (b) 17 healthy men who were receiving a continuous infusion of epinephrine (30 ng/kg per min) started either 3 h (EPI-3; n = 5) or 24 h (EPI-24; n = 6) were studied after intravenous injection of LPS (2 ng/kg, lot EC-5). EPI-3 inhibited LPS-induced in vivo TNF appearance and also increased IL-10 release (both P < 0.005 versus LPS), whereas EPI-24 only attenuated TNF secretion (P = 0.05). In separate in vitro experiments in whole blood, epinephrine increased LPS-induced IL-10 release by a combined effect on alpha and beta adrenergic receptors. Further, in LPS-stimulated blood, the increase on IL-10 levels caused by epinephrine only marginally contributed to concurrent inhibition of TNF production. Epinephrine, either endogenously produced or administered as a component of sepsis treatment, may have a net antiinflammatory effect on the cytokine network early in the course of systemic infection.
T van der Poll, S M Coyle, K Barbosa, C C Braxton, S F Lowry
Usage data is cumulative from February 2024 through February 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 280 | 105 |
51 | 59 | |
Citation downloads | 42 | 0 |
Totals | 373 | 164 |
Total Views | 537 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.