Affinity-purified rabbit anti-neutrophil cytochrome b light or heavy chain antibodies were used to immunocytochemically and biochemically localize cytochrome b in neutrophils and eosinophils. The antibodies were monospecific, recognizing polypeptides of 91 and 22 kD, respectively, on Western blots of whole neutrophil extracts. The antibodies were used in Western blot analysis of subcellular fractions of purified neutrophils to confirm that the distribution of cytochrome b spectral absorbance matched that of the two subunits. Thin sections of cryofixed, molecular distillation-dried granulocytes were labeled with the anti-cytochrome b antibodies, followed by incubation with biotin-conjugated secondary antibody, and final labeling with streptavidin-conjugated colloidal gold. Electron microscopy revealed that the cytochrome b light and heavy chains were localized primarily (80%) to 0.1-0.2-micron round or elliptical granule-like structures in neutrophils and 0.4-0.5-micron granules in eosinophils. Approximately 20% of the cytochrome b was localized to the surface, confirming the subcellular fractionation studies. Double staining experiments on the neutrophils, using polyclonal rabbit anti-lactoferrin antibody, indicated that the cytochrome-bearing structures also contained lactoferrin and thus were specific granules. When the analysis was performed on neutrophils that had phagocytosed Staphylococcus aureus, cytochrome b was found in the phagosomal membrane adjoining the bacterial cell wall.
A J Jesaitis, E S Buescher, D Harrison, M T Quinn, C A Parkos, S Livesey, J Linner
Usage data is cumulative from August 2023 through August 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 137 | 0 |
52 | 36 | |
Figure | 0 | 19 |
Scanned page | 285 | 12 |
Citation downloads | 13 | 0 |
Totals | 487 | 67 |
Total Views | 554 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.