Secretory component (SC) is a glycoprotein that mediates the transcellular transport of polymeric immunoglobulins into external secretions. SC is synthesized and inserted into the plasma membrane of epithelial cells and hepatocytes as a transmembrane protein, where it serves as a receptor for polymeric immunoglobulins. SC is posttranslationally cleaved to a soluble protein before secretion into external fluids. In the rat jejunum, we observed that the molecular weights of both the major membrane and soluble forms of SC were 10,000-20,000 smaller than the comparable hepatic forms of the glycoprotein. We therefore set out to determine the reason for the differences in size of SC between these two tissues. The smaller size of jejunal SC was not due to the action of pancreatic proteases or differential glycosylation but was due to proteolysis by a jejunal brush border protease. The protease was characterized as a metalloprotease, with a pH optimum of approximately 5. It is present in jejunal, ileal, and renal tubular brush borders as an integral membrane constituent. When the protease was inhibited in vivo, conversion of jejunal secretory component to the smaller size was partially prevented. Thus, in the rat jejunum, SC undergoes two posttranslational proteolytic events: conversion of membrane secretory component to the soluble form and conversion of soluble SC to a smaller size by a previously undescribed brush border protease.
D J Ahnen, J R Singleton, T C Hoops, T M Kloppel
Usage data is cumulative from March 2024 through March 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 65 | 0 |
40 | 15 | |
Figure | 0 | 4 |
Scanned page | 220 | 6 |
Citation downloads | 37 | 0 |
Totals | 362 | 25 |
Total Views | 387 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.