A coagulation Factor V inhibitor developed in a man 75 yr of age in association with an anaplastic malignancy and drug treatment (including the aminoglycoside antibiotic, gentamicin). The patient did not bleed abnormally, despite both surgical challenge and plasma Factor V activity of less than 1%. The inhibited plasma had grossly prolonged prothrombin and activated partial thromboplastin times, but a normal thrombin time. Mixing studies indicated progressive coagulation inhibition with normal plasma, but not with Factor V-deficient plasma, and reversal of coagulation inhibition by the addition of bovine Factor V to the patient's plasma. 1 ml of patient plasma inhibited the Factor V activity of 90 ml of normal human plasma. The inhibitor was isolated by sequential affinity chromatography on protein A-Sepharose and Factor V-Sepharose. The IgG isolate markedly inhibits the activity of prothrombinase assembled from purified Factors Xa and Va, calcium ion, and phospholipid vesicles, and partially inhibits prothrombinase assembled from purified Factor Xa, calcium ion, and normal platelets. The Factor V of platelets, however, appears relatively inaccessible to the antibody, inasmuch as platelets isolated from whole blood supplemented for 8 h with the antibody functioned normally with respect to platelet Factor V-mediated prothrombinase function. The absence of obvious hemorrhagic difficulties in the patient, the total inhibition of plasma Factor V by the inhibitor, and the apparent inaccessibility of platelet Factor V to the inhibitor specifically implicate platelet Factor V in the maintenance of hemostasis.
M E Nesheim, W L Nichols, T L Cole, J G Houston, R B Schenk, K G Mann, E J Bowie
Usage data is cumulative from November 2023 through November 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 153 | 0 |
100 | 46 | |
Figure | 0 | 4 |
Scanned page | 486 | 15 |
Citation downloads | 46 | 0 |
Totals | 785 | 65 |
Total Views | 850 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.