Changes in the oral intake of phosphorus could induce the reported changes in the serum concentration of 1,25-dihydroxyvitamin D (1,25-(OH)2D) by inducing changes in its production rate (PR) or metabolic clearance rate (MCR), or both. To investigate these possibilities, we employed the constant infusion equilibrium technique to measure the PR and MCR of 1,25-(OH)2D in six healthy men in whom the oral intake of phosphorus was initially maintained at 1,500 mg/70 kg body weight per d for 9 d, then restricted to 500 mg/d (coupled with oral administration of aluminum hydroxide) for 10 d, and then supplemented to 3,000 mg/d for 10 d. With phosphorus restriction, the serum concentration of 1,25-(OH)2D increased by 80% from a mean of 38 +/- 3 to 68 +/- 6 pg/ml, P less than 0.001; the PR increased from 1.8 +/- 0.2 to 3.8 +/- 0.6 micrograms/d, P less than 0.005; the MCR did not change significantly. The fasting serum concentration of phosphorus decreased from 3.5 +/- 0.2 to 2.6 +/- 0.2 mg/dl, P less than 0.01. With phosphorus supplementation, the serum concentration of 1,25-(OH)2D decreased abruptly, reaching a nadir within 2 to 4 d; after 10 d of supplementation, the mean concentration of 27 +/- 4 pg/ml was lower by 29%, P less than 0.01, than the value measured when phosphorus intake was normal. The PR decreased to 1.3 +/- 0.2 micrograms/d, P less than 0.05; the MCR did not change significantly. The fasting serum concentration of phosphorus increased significantly, but only initially. These data demonstrate that in healthy men, reductions and increases in the oral intake of phosphorus can induce rapidly occurring, large, inverse, and persisting changes in the serum concentration of 1,25-(OH)2D. Changes in the PR of 1,25-(OH)2D account entirely for the phosphorus-induced changes in serum concentration of this hormone.
A A Portale, B P Halloran, M M Murphy, R C Morris Jr
Usage data is cumulative from January 2024 through January 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 172 | 5 |
63 | 21 | |
Scanned page | 201 | 10 |
Citation downloads | 49 | 0 |
Totals | 485 | 36 |
Total Views | 521 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.