Recent studies provide evidence for extrarenal production of 1 alpha ,25-dihydroxyvitamin D [1 alpha ,25(OH)2D]. To investigate this possibility, serum vitamin D, 25-hydroxyvitamin D (25-OHD), 24,25-dihydroxyvitamin D [24,25(OH)2D], and 1 alpha ,25(OH)2D were measured in eight adult anephric subjects. All were undergoing hemodialysis and three of them were receiving vitamin D, 50,000 or 100,000 U/d. Serum vitamin D was elevated in two of the patients given vitamin D and was abnormally low in the others. Mean serum 25-OHD was increased in patients given vitamin D (94.0 +/- 7.6 ng/ml) and was normal in the others (16.4 +/- 0.9 ng/ml, P less than 0.001). Mean serum 24,25(OH)2D was normal in patients given vitamin D (1.38 +/- 0.27 ng/ml) and was low in the others (0.25 +/- 0.08 ng/ml, P less than 0.001). Serum 24,25(OH)2D correlated significantly with serum 25-OHD (r = 0.848, P less than 0.01). Mean serum 1 alpha ,25(OH)2D determined by receptor assay was 5.8 +/- 1.9 pg/ml in patients who were not given vitamin D and was 14.1 +/- 0.6 in those who were given vitamin D (P less than 0.001). Serum 1 alpha ,25(OH)2D correlated significantly with serum 25-OHD (r = 0.911, P less than 0.01). Mean serum 1 alpha ,25(OH)2D, measured by bioassay, was 8.3 +/- 1.9 pg/ml in patients who were given vitamin D and was 15.9 +/- 2.4 pg/ml in those who were given vitamin D (P less than 0.05). There was a significant correlation between the values for serum 1 alpha ,25(OH)2D obtained with the two methods (r = 0.728, P less than 0.01). The results (a) provide evidence in man for extrarenal production of both 24,25(OH)2D and, by two independent assays, of 1 alpha , 25(OH)2D, and (b) indicate that serum values of the two dihydroxy metabolites of vitamin D in anephric subjects vary with the serum concentration of the precursor 25-OHD.
P W Lambert, P H Stern, R C Avioli, N C Brackett, R T Turner, A Greene, I Y Fu, N H Bell
Usage data is cumulative from November 2023 through November 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 208 | 0 |
100 | 21 | |
Scanned page | 183 | 4 |
Citation downloads | 41 | 0 |
Totals | 532 | 25 |
Total Views | 557 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.