To study the influence of hypometabolism on evolving myocardial infarction in a model with intact autoregulation, we investigated 53 awake dogs after coronary artery occlusion. Severe hypothyroidism was induced by the intravenous administration of 131I. Animals were instrumented to obtain hemodynamic measurements, and regional myocardial blood flow was measured with radioactive microspheres. Infarct size was determined by the creatine kinase depletion method, and dysrhythmia analysis was performed from 24-h Holter monitor tapes in animals matched for infarct size. The microarchitecture of hypothyroid myocardium was determined by the electron microscope. Before coronary occlusion, mean systemic pressure in hypothyroid dogs was reduced by 14% and cardiac output reduced by 32%, with no change in left ventricular end-diastolic pressure, first derivative of left ventricular pressure rise, (dP/dt), or heart rate. After coronary occlusion, there was deterioration in hemodynamic measurements in both groups, with lower absolute levels of mean systemic blood pressure and cardiac output obtained in hypothyroid dogs. Hypothyroidism was detrimental to evolving infarction with a 36% increase in infarct size present in hypothyroid dogs (30 +/- 2%) compared to euthyroid controls (22 +/- 3%), P less than 0.05. Dysrhythmias were more severe in hypothyroid dogs. There were no changes in the relationship between regional myocardial blood flow and the extent of infarction after coronary occlusion. Abnormalities in microarchitecture were present in hypothyroid dog myocardium. Severe hypometabolism in this model was associated with alterations in hemodynamics, more severe dysrhythmias and changes in microarchitecture. The combined effect of these alterations resulted in an overall detrimental influence of hypothyroidism on evolving myocardial necrosis in this model.
R P Karlsberg, D A Friscia, W S Aronow, S S Sekhon
Usage data is cumulative from February 2024 through February 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 95 | 0 |
39 | 22 | |
Scanned page | 258 | 1 |
Citation downloads | 34 | 0 |
Totals | 426 | 23 |
Total Views | 449 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.