Although prostaglandins E2 and F2α have been suggested as mediators of the pulmonary hypertension seen after endotoxin infusion or during alveolar hypoxia, their precursors, the endoperoxides (prostaglandins G2 and H2) are much more potent vasoconstrictors in vitro. In this study we compared the effects of prostaglandin (PG)H2, a stable 9-methylene ether analogue of PGH2 (PGH2-A), PGE2, and PGF2α on pulmonary hemodynamics in awake sheep. The animals were prepared to allow for measurement of (a) lung lymph flow; (b) plasma and lymph protein concentration; (c) systemic and pulmonary vascular pressures; and (d) cardiac output. We also determined the effect of prolonged PGH2-A infusions on lung fluid balance and vascular permeability by indicator dilution methods, and by assessing the response of lung lymph. Both PGH2 and PGH2-A caused a dose-related increase in pulmonary artery pressure: 0.25 μg/kg × min tripled pulmonary vascular resistance without substantially affecting systemic pressures. Both were 100 times more potent than PGE2 or PGF2α in this preparation. PGH2-A, as our analysis of lung lymph and indicator dilution measurements show, does not increase the permeability of exchanging vessels in the lung to fluid and protein. It does, however, augment lung fluid transport by increasing hydrostatic pressure in the pulmonary circulation. We conclude: (a) that PGH2 is likely to be an important mediator of pulmonary vasoconstriction; (b) its effects are probably not a result of its metabolites PGE2 or PGF2α.
Ronald E. Bowers, Earl F. Ellis, Kenneth L. Brigham, John A. Oates
Usage data is cumulative from November 2023 through November 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 129 | 0 |
71 | 18 | |
Scanned page | 220 | 1 |
Citation downloads | 30 | 0 |
Totals | 450 | 19 |
Total Views | 469 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.