The effects of coronary artery reperfusion at 1 and 3 h after occlusion on infarct size (IS) in the conscious dog were compared with a second group of dogs that were not reperfused (24 h occlusion). Infarct size was calculated from creatine kinase (CK) appearing in blood samples (ISs) and myocardial CK depletion (ISm), and determined from gross and histological inspection of the pathological tissue (ISp). Under both conditions, ISm correlated well with ISp. In dogs with 24-h coronary occlusions, ISs correlated well with ISm (ISs = 14.26 + 1.18 × ISm, r = 0.92). In reperfused dogs, the relationship remained linear but was altered (ISs = 15.33 + 2.07 × ISm, r = 0.89). The slope was significantly greater, P <0.05, than that observed for dogs that were not reperfused, suggesting that more CK appeared in serum per gram of infarct. Similarly, significantly different relationships were observed in the reperfused and nonreperfused dogs, when ISs was compared with ISp. Moreover, the configuration of the serial blood CK curve was changed significantly by reperfusion. In dogs with a 24-h occlusion, CK rose gradually to a peak at 11.4±0.5 h. In dogs reperfused at 3 h, CK rose sharply at 3 h and reached a peak at 6.8±0.5 h, significantly earlier (P <0.01) than occurred in dogs reperfused at 1 h, i.e., when the peak occurred at 4.2±0.4 h. The rapid appearance of CK in blood after reperfusion at 1 and 3 h suggested a washout phenomena. Thus, reperfusion alters the shape of the serial blood CK curve and results in a different linear relationship between calculated and measured infarct size, resulting in greater recovery of CK in blood per unit of infarcted myocardium.
Stephen F. Vatner, Hank Baig, W. Thomas Manders, Peter R. Maroko
Usage data is cumulative from December 2023 through December 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 190 | 0 |
112 | 20 | |
Scanned page | 337 | 5 |
Citation downloads | 46 | 0 |
Totals | 685 | 25 |
Total Views | 710 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.