We studied the effects of acute pharmacologic and hemodynamic interventions on isovolumic left ventricular relaxation in 19 conscious dogs using micromanometer tip catheters. Isoproterenol (11 studies) augmented peak rate of rise of left ventricular pressure [(+) dP/dt] by 1,275±227 (SE) mm Hg/s (P < 0.001) and dP/dt at an isopressure point of 35 mm Hg during isovolumic relaxation [(−) dP/dt35] by 435±80 mm Hg/s (P < 0.001). Peak (−) dP/dt decreased by 467±89 mm Hg/s (P < 0.002). The time constant, T, derived from the logarithmic fall of pressure during isovolumic relaxation, shortened from 20±2.8 to 14.9±1.8 ms (P < 0.003). Calcium (11 studies) increased peak (+) dP/dt and (−) dP/dt35 (both P < 0.0001); peak (−) dP/dt was unchanged. T shortened from 20.4±1.8 to 17.3±1.5 ms (P < 0.002). Volume (13 studies) did not affect either dP/dt or T. Phenylephrine (13 studies) augmented peak (−) dP/dt, but reduced (−) dP/dt35 (both P < 0.01); T lengthened from 22.1±1.5 to 32.5±1.5 ms (P < 0.01). In 15 studies, rapid atrial pacing increased peak (+) dP/dt and (−) dP/dt35 (both P < 0.01). In the first post-pacing beat, peak (−) dP/dt and (−) dP/dt35 decreased (both P < 0.01), although peak (+) dP/dt increased further. T paralleled values of (−) dP/dt35. In five dogs, beta adrenergic blockade had no significant effect on any variable after calcium, volume, or phenylephrine infusion or during or after atrial pacing when the pre-and post-propranolol states were compared.
Joel S. Karliner, Martin M. Lewinter, Felix Mahler, Robert Engler, Robert A. O'Rourke
Usage data is cumulative from March 2024 through March 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 154 | 1 |
78 | 30 | |
Scanned page | 516 | 1 |
Citation downloads | 76 | 0 |
Totals | 824 | 32 |
Total Views | 856 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.