The peak rate of systolic wall thickening (pdTw/dt) in regions of the left ventricle was determined by biplane roentgen videometry in 60 patients before and a median of 14 mo after aorto-coronary bypass graft surgery. The left ventricular ejection fraction, stroke volume, and end-diastolic volume and pressure did not change significantly after surgery in the presence of patent or occluded grafts (P greater than 0.05). Statistically significant increases occurred in the peak rate of systolic wall thickening regions supplied by patent bypass grafts, and significant decreases occurred in regions with occluded grafts (P less than 0.01). Of 42 preoperatively hypokinetic regions (pdTw/dt greater than 0 less than 5.0 cm/s) supplied by a patent graft, 30 improved by an average of 2.6 cm/s after operation; 18 returned to normal. Failure of 24 hypokinetic regions to improve to normal was associated with myocardial infarction in 11 or with late postoperative graft blood flows of less than 60 ml/min measured by videodensitometry, in 10. All seven preoperatively akinetic (pdTw/dt=0) or dyskinetic (pdTw/dt less than 0) regions did not improve after the operation despite the fact that, in five of the seven, coronary bypass flows were over 60 ml/min. All eight preoperatively hypokinetic regions supplied by coronary artery graft flows of less than or equal 40 ml/min failed to improve to normal after operation. All nine preoperatively hypokinetic regions supplied by coronary artery graft flows of over 60 ml/min improved to normal after surgery. Late postoperative coronary artery bypass graft flows, the functional status of the myocardium, the status and distribution of the native coronary circulation, and decreased regional function elsewhere in the ventricle must all be considered when regional left ventricular function is interpreted.
J H Chesebro, E L Ritman, R L Frye, H C Smith, D C Connolly, B D Rutherford, G D Davis, G K Danielson, J R Pluth, D A Barnhorst, R B Wallace
Usage data is cumulative from March 2024 through March 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 96 | 2 |
61 | 17 | |
Scanned page | 345 | 3 |
Citation downloads | 51 | 0 |
Totals | 553 | 22 |
Total Views | 575 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.