An unusual electrophoretic pattern of the urine from a patient with malignant lymphoma was observed. One of the major proteins, identified Zn-alpha2-glycoprotein (Zn-alpha2), was isolated from the urine and partly characterized. The Stokes radius was found to be 3.24 nm and the molecular weight, determined by sodium dodecyl sulfate polyacrylamide electrophoresis, 42,000. The plasma level in healthy individuals was 39 +/- 7 (SD) mg/liter. In 12 of 25 healthy individuals, Zn-alpha2 was measurable in the urine and was found to be 1.0 +/- 1.1 mg/liter. In 23 patients with chronic glomerulonephritis (CGN), in 9 with proximal tubular dysfunction (PTD), in 23 with various renal diseases (VRD), and in 10 with malignant lymphoma, the plasma level and the urinary excretion were compared with those of albumin (mol wt 67,000) and of the retinol-binding protein (RBP, mol wt 21,000). A close correlation was found between the urine-to-plasma (U/P) ratios of Zn-alpha2 and albumin in the patients with CGN, whereas in the PTD patients the U/P ratios of Zn-alpha2 and RBP were correlated. No significant renal arteriovenous difference in Zn-alpha2 could be demonstrated. The Zn-alpha2 excretion was increased also in two patients with malignant lymphoma and proteinuria of a tubular pattern. The plasma Zn-alpha2 varied inversely with the glomerular filtration rate in the patients with renal disease, but was normal in those with malignant lymphoma. The results are consistent with the assumption of a sieving coefficient of Zn-alpha2, substantially exceeding that of albumin, but notably lower than that of smaller low-molecular-weight proteins. An increased excretion of Zn-alpha2 may be due to increased glomerular permeability as well as to defective proximal tubular reabsorption.
R Ekman, B G Johansson, U Ravnskov
Usage data is cumulative from March 2024 through March 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 122 | 7 |
56 | 22 | |
Scanned page | 300 | 2 |
Citation downloads | 44 | 0 |
Totals | 522 | 31 |
Total Views | 553 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.