To test an artificial surfactant in vivo, six 120-d gestational age lambs were treated at birth with a mixture of a 9:1 M ratio of [14C]dipalmitoyl phosphatidylcholine (DPC) and phosphatidylglycerol at a dose of 100 mg DPC/kg. Nine other lambs were not treated. The mean PO2 values of the lambs treated with artificial surfactant were 65.7 +/- 11 mm Hg vs. 24.8 +/- 1.6 mm Hg for the untreated lambs (P less than 0.001). All lambs then were treated with 50 mg/natural surfactant lipid per kg, which promptly improved PO2 in all lambs. The PO2 values of those lambs previously treated with artificial surfactant remained greater than 100 mm Hg for 2.5 +/- 0.5 h vs. 0.9 +/- 0.3 h for lambs untreated with artificial surfactant (P less than 0.01). The pH and PCO2 values were not strikingly different between the two groups of lambs. Airway samples taken from lambs treated with artificial surfactant before treatment with natural surfactant had minimal surface tensions of 32 +/- 2.9 dyn/cm, whereas the artificial surfactant reisolated from these samples by centrifugation had minimum surface tension of 0 dyn/cm. The minimum surface tension of artificial surfactant was inhibited by fetal lung fluid from the premature lambs, whereas the minimum surface tension of natural surfactant was much less sensitive to inhibition. Artificial surfactant did not improve the pressure-volume characteristics of unventilated premature lung, whereas natural surfactant did. The change in specific activity of [14C]DPC following treatment with natural surfactant indicated that approximately 50% of the DPC initially administered was no longer associated with the airways.
M Ikegami, A Jobe, H Jacobs, S J Jones
Usage data is cumulative from December 2023 through December 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 151 | 0 |
92 | 15 | |
Scanned page | 213 | 1 |
Citation downloads | 38 | 0 |
Totals | 494 | 16 |
Total Views | 510 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.